Brand Name : SWP
Model Number : SWP-ASR232-3-3/C3/U/P2/J6/T
Certification : ISO,MC,CTP
Place of Origin : China
MOQ : 1 set
Price : $1300-1850/set
Payment Terms : T/T, L/C, Western Union
Supply Ability : 1000set/week
Delivery Time : 1 week
Packaging Details : carton
Display : color chart
Communication : RS485
USB port : yes
Language : multi language
Size : 288×288×193mm
Max : 32 channels
input : relay
Function : Gas accumulation
Overview
In order to correctly use SWP-ASR series, please read carefully
this operating manual. For safety reason, grounding is very
importance. After finishing the installation, confirmed that power
lines have connected correctly otherwise the instrument outer
covering might be with approximately 110 V. Communication ports
connection should be under power off condition.
Please do not disassemble the instrument. Contact company service
center or the local business agent if the instrument is breakdown.
Please maintain the instrument surface clean with soft dry cloth.
The gasoline or alcohol and any organic solvent are not allowed for
surface cleaning.
1.1Features
1.1.1Input & Output
Input signal | Analog Input | T.C: B,S,K,E,T,J,W |
RTD: PT100,CU50 | ||
DC: 0-5V, 1-5V, 0-100mV, 0-20mV, 4-20mA | ||
Pulse Input | Rectangular, sine or triangular wave: | |
Amplidute Range>= 4V, frequency 0 - 15KHz | ||
Output Signal | Analog output | DC Current: 0-10mA, 4-20mA |
DC Voltage: 0-5V, 1-5V | ||
Relay contact rating | Relay: 220V/3A or DC 24V/5A | |
SCR: 400V/0.5A | ||
SSR: 6-9V/0.05A | ||
Power Output | DC 24V/30mA |
1.1.2Performance
Accuracy | 0.5%FS±1digit or 0.2%FS±1digit (ignored level: 0-25.5%FS) |
Range | .-9999-99999 |
Sampling Period | 0.25 second |
Interrecord Time | 1 second - 4 minutes |
Display mode | High resolution, brightness adjustable, wide view angle and bright
TFT |
Parameters setting | By Key nods or upper linking computer setting. Security lock function is available |
| 4 alarm points per channel are available. Upper/lower alarm,
rate-of-change and differential limit; Alarm output delay, alarm
delay high to low, external connection |
Communication port | RS-232,RS-485: Buad rate:1200 – 115200 bps. |
Control action | Hysteresis ON/OFF relay output (AC220V/3A) is selectable. |
Printer | TPμP-A40 micro printer is recommended. |
Operating | Ambient Temperature -15 — 60 ℃, Humidity ≤ 85%RH |
Supply Voltage | 95 - 260VAC 50-60Hz |
Power consume | ≤ 40W |
Weight | Approx 8600 g (ASR200 series) |
SWP-ASR100 MODEL SELECTION:
Model | Spec.code | Additional code | description | |
ASR101 | ASR100 (1 ch) | |||
ASR102 | ASR100 (2 ch) (standard configuration) | |||
ASR103 | ASR100 (3 ch) | |||
ASR104 | ASR100 (4 ch) | |||
ASR105 | ASR100 (5 ch) | |||
ASR106 | ASR100 (6 ch) | |||
ASR107 | ASR100 (7 ch) | |||
ASR108 | ASR100 (8 ch) | |||
ASR109 | ASR100 (9 ch) | |||
ASR110 | ASR100 (10 ch) | |||
ASR111 | ASR100 (11 ch) | |||
ASR112 | ASR100 (12 ch) | |||
Memory capacity | -1 | 32 Mb (default) | ||
-2 | 64 Mb | |||
-3 | 160 Mb | |||
Languages | 0 | Simple Chinese | ||
-1 | English | |||
-2 | Traditional Chinese | |||
-3 | Multi-languages | |||
Specification | /C2 | RS-232 comm port *1 *2 | ||
/C3 | RS-485 comm port *1 | |||
/P(1-6) | No. of DC24V Power outpot | |||
/AO(1-4) | No. of linear output *3 | |||
/F(1-4) | No. of frequency input *3 | |||
/J(1-12) | No. of (Normally open) Relays | |||
/JB(1-4) | No of (Normally open/close) relays | |||
/L | Flow accumulating function (included report function) | |||
/T | Nutual gas operating function (included report functions) | |||
/PID | PID control functions |
8 Maintainance
In order to ensure the instrument working properly, regular
maintanence is necessary.
8.1Connection inspection
Ensure L,N,G power connection points are tighten.(Grounding
resistance must ≤ 100 Ω) Ensure input signals wiring are properly
contacted.
8.2Operating environment
Operating temperature:-15℃—60℃;Humidity:10%—85%(without
condensated);
Please do not use the instrument under direct sunlight, high
humidity, corrosive gases and strength electromagnetism conditions.
The front installation panel thickness should be ≥ 4mm Please
install the instrument with carefully.
8.3Replace spoilt fuse
Steps:
-Ensure power off the instrument
-Disassemble the front panel with 2 screws under front cover.
-Pull out the power board from the rack.
-Replace fuse
-Re-install.
-Power up and check the working status.
![]() |
SWP paperless recorder SWP-ASR232-3-3/C3/U/P2/J6/T 32channels gas accumulation relay Images |