SWP paperless recorder SWP-ASR224-64-3/C2/P/F2/U 24 channels frequecy input

Beijing Keymeter Technology co.,Ltd

SWP paperless recorder SWP-ASR224-64-3/C2/P/F2/U 24 channels frequecy input

  • 1
  • 2
  • 3

Brand Name : SWP

Model Number : SWP-ASR224-64-3/C2/P/F2/U

Certification : ISO,MC,CTP

Place of Origin : China

MOQ : 1 set

Price : $1200-1750/set

Payment Terms : T/T, L/C, Western Union

Supply Ability : 1000set/week

Delivery Time : 1 week

Packaging Details : carton

Display : color chart

Communication : RS232

USB port : yes

Language : multi language

Size : 288×288×193mm

Max : 24 channels

input : frequency

Contact Now

Overview
In order to correctly use SWP-ASR series, please read carefully this operating manual. For safety reason, grounding is very importance. After finishing the installation, confirmed that power lines have connected correctly otherwise the instrument outer covering might be with approximately 110 V. Communication ports connection should be under power off condition.
Please do not disassemble the instrument. Contact company service center or the local business agent if the instrument is breakdown. Please maintain the instrument surface clean with soft dry cloth. The gasoline or alcohol and any organic solvent are not allowed for surface cleaning.

1.1Features
1.1.1Input & Output

Input signalAnalog InputT.C: B,S,K,E,T,J,W
RTD: PT100,CU50
DC: 0-5V, 1-5V, 0-100mV, 0-20mV, 4-20mA
Pulse InputRectangular, sine or triangular wave:
Amplidute Range>= 4V, frequency 0 - 15KHz
Output SignalAnalog outputDC Current: 0-10mA, 4-20mA
DC Voltage: 0-5V, 1-5V
Relay contact ratingRelay: 220V/3A or DC 24V/5A
SCR: 400V/0.5A
SSR: 6-9V/0.05A
Power OutputDC 24V/30mA



1.1.2Performance

Accuracy0.5%FS±1digit or 0.2%FS±1digit (ignored level: 0-25.5%FS)
Range.-9999-99999
Sampling Period0.25 second
Interrecord Time1 second - 4 minutes
Display mode

High resolution, brightness adjustable, wide view angle and bright TFT
color LCD (640x480) with saving screen (10.4‖ for ASR200 series)

Parameters settingBy Key nods or upper linking computer setting. Security lock function is available


Alarm

4 alarm points per channel are available. Upper/lower alarm, rate-of-change and differential limit; Alarm output delay, alarm delay high to low, external connection
sound available, max 12 latest alarm messages are saved per channel.

Communication portRS-232,RS-485: Buad rate:1200 – 115200 bps.
Control actionHysteresis ON/OFF relay output (AC220V/3A) is selectable.
PrinterTPμP-A40 micro printer is recommended.

Operating
environment

Ambient Temperature -15 — 60 ℃, Humidity ≤ 85%RH
Supply Voltage95 - 260VAC 50-60Hz
Power consume≤ 40W
WeightApprox 8600 g (ASR200 series)


SWP-ASR100 MODEL SELECTION:

ModelSpec.codeAdditional codedescription
ASR101ASR100 (1 ch)
ASR102ASR100 (2 ch) (standard configuration)
ASR103ASR100 (3 ch)
ASR104ASR100 (4 ch)
ASR105ASR100 (5 ch)
ASR106ASR100 (6 ch)
ASR107ASR100 (7 ch)
ASR108ASR100 (8 ch)
ASR109ASR100 (9 ch)
ASR110ASR100 (10 ch)
ASR111ASR100 (11 ch)
ASR112ASR100 (12 ch)
Memory capacity-132 Mb (default)
-264 Mb
-3160 Mb
Languages0Simple Chinese
-1English
-2Traditional Chinese
-3Multi-languages
Specification/C2RS-232 comm port *1 *2
/C3RS-485 comm port *1
/P(1-6)No. of DC24V Power outpot
/AO(1-4)No. of linear output *3
/F(1-4)No. of frequency input *3
/J(1-12)No. of (Normally open) Relays
/JB(1-4)No of (Normally open/close) relays
/LFlow accumulating function (included report function)
/TNutual gas operating function (included report functions)
/PIDPID control functions





8.4Calibration
Please ensure instrument calibration yearly. There are some calibration tools recommended:
Standard DC voltage signal generator (Output: 20mV—20V Accuracy ±0.005%); Variable resistor (Output: 0.1—500Ω Accuracy ±0.001% Resolution 0.001 Ω).
Calibration process:
1 Power up instrument with correct GND, warmup 30 minutes or above; 2 Ensure environments is instrument acceptable condition;
3Input measurement points (0 ,50% ,100%) of measurement range, record down input value Vs measuring value;
4Amend zero and P offset value in the instrument according the following formular.

Measuring value1 × Proportion + Zero = calibrated value1

Measuring value2 × Proportion + Zero = Calibrated value2



























Wholesale SWP paperless recorder SWP-ASR224-64-3/C2/P/F2/U 24 channels frequecy input from china suppliers

SWP paperless recorder SWP-ASR224-64-3/C2/P/F2/U 24 channels frequecy input Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Keymeter Technology co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0