SWP20 voltage/current/frequency transforming module is a minitype
temperature transforming module with inserting structure, which
transforms voltage (V or mA) and current (mA) signals into the
insulated output signals of 1~5V DC or 4~20mA DC that are
proportional to the input.
SWP20 voltage/current/frequency transforming module is an
intelligent transmitting module, which can linear-rectify
high-precisely various non-linear input signals by using
microprocessor. It, if fitted with SWP20SH displaying module, can
digitally display the measuring value corresponding to input
signals.
SWP20 voltage/current/frequency transforming module can select AC
or DC electrical source and 1~5V DC or 4~20mA DC output signal. The
transmitting output is insulated with mainframe. It also has
wire-broken protective function.
SWP20 voltage/current/frequency transforming module also has a
channel of serial communicating output, which can select RS-232,
RS-485 or RS-422 communicating interface. The communicating output
is insulated with mainframe.
MAIN SPECIFICATIONS
·INPUT
mV input: 3~100mV
V input: 0~100V DC (absolute value is less than 100V)
mA input: 0~20mA DC
·FREQUENCY: Amplitude ≥4V, Δf≤5KHz
·INPUT RESISTANCE: More than 250KΩ(when input is 1~5V)
250KΩ(when input is 4~20mA)
·ZERO EXCURSION: -100% ~ +100% of input measuring range
·SOURCE RESISTANCE: Less than 500Ω(effecting value: less than
±0.1%/150Ω)
·OUTPUT: two-channel output insulated
The first channel: 1~5V DC or 4~20mA DC (selectable)
The second output: 1~5V DC or 4~20mA DC
Or position alarm control: relay point ON/OFF output
(AC 220V/0.5A, DC V/1A, resistance load)
Or serial communicating output:
RS-232, RS-485 or RS-422 communicating interface
·LOAD RESISTANCE: less than 250Ω(if output is 1~5V DC)
·ALLOWABLE LOAD RESISTANCE: 0~600Ω(if output is 4~20mA DC)
·PRECISION: ±0.5%FS or ±0.2%FS ±1byte
·PARAMETER SET: set by SWP20PCA programmer
·WIRE-BROKEN PROTECT: provided only when input is mV
·RESPONDING TIME
mV input: about 500ms(time constant)
V or mA input: about 100ms(time constant)
·CO-MODULE SUPPRESS RATIO: more than 120dB when 50Hz
·INSULATING: input, output and electric source are insulated from
each other
·POWER SUPPLY: AC or DC AC: 90~265V DC: 24V±10%
·POWER CONSUMPSION: when 220V AC≤ 3W when 24V DC≤ 2.5W
·AMBIENT TEMPERATURE: 0~55℃
·RELATIVE HUMIDITY: 5~99%RH(not dew)
·INSULATING RESISTANCE:
Between various ends and earthing end: 100MΩ / 500V DC
·INSULATING ITENSITY:
Between power end and earthing end: 1500V AC, 1 minute
Between input/output end and earthing end: 500V DC, 1 minute
·STRUCTURE: Minitype of inserting structure Color
·WEIGHT: main body: about 180g socket: about 80g
·MAINTENANCE: The mainbody can be replaced under installing wiring.
The communicating interface of SWP20PCA programmer locates in the
front of main body.
MODEL SELECTION
SWP20 | □ | IC | □ | □ | —□ | ( ) | EXPLAIN |
1 | | one-channel |
2 | | two-channel |
1 | | | | the 1st output is 1~5V |
2 | | | | the 1st output is 4~20mA |
0 | | | without the 2nd channel output (onittable) |
1 | | | the 2nd output is 1~5V output |
2 | | | the 2nd output is 4~20mA |
3 | | | the 2nd output is alarm point control |
4 | | | the 2nd output is RS-232 communicating interface |
5 | | | the 2nd output is RS-422 communicating interface |
6 | | | the 2nd output is RS-485 communicating interface |
7 | | | the 2nd output is a special standard |
* | | input graduating code (refer to table 3) |
* | write down input range (refer to table 3) |
Code example: SWP201IC1-N ( 0~100mV DC)
SWP201IC16-F ( 0~5K HZ)
TABLE 3: INPUT SIGNAL GRADUATION
| Code | Input Signal | Measuring Range | Note |
Input Signal | N | mV input. Write down input range within 0 ~ 100 mV DC into ( ) | 0~100 mV DC | The left range is the maximum, within which a user can determine
own range by modifying the internal parameters of the transmitter. |
V | V input. Write down input range within 0 ~ 100 V DC into ( ) | 0~100 V DC |
I | mA input. Write down input range within 0 ~ 20 mA DC into ( ) | 0~20 mA DC |